RCI DE8310 Delayed Egress

The dormakaba RCI DE8310 is an all-in-one delayed egress maglock for single outswinging perimeter doors. A delayed egress lock holds the door locked for a set time after someone pushes on it, sounds an alarm, and then releases so that people can leave. The DE8310 detects when pressure is applied to the door and releases after a field-selectable delay of 15 or 30 seconds, with a field-selectable nuisance delay of 0 to 3 seconds.

Because the DE8310 adds delayed egress without replacing the existing door hardware, it is an affordable perimeter door solution for loss prevention, life safety and traffic control. The electromagnet provides up to 1,200 lbf (5,338 N) of holding force, auto-senses 12 to 24 VDC and draws 490 mA at 12 VDC (base unit). The lock is fail-safe: it releases when power is removed.

What is included: the base unit DE8310 comes with a 914 external alarm sounder, a 960 keyswitch for reset and override, and a building code sign. The DE8310-S has a built-in sounder instead. A red/green light panel shows the door status locally, and dry-contact single pole double throw (SPDT) and double pole double throw (DPDT) relays provide local and remote monitoring.

Code and listings: provision for IBC, SBC, NFPA 101, UBC, BOCA or National Building Code of Canada compliance; UL 294 (Underwriters Laboratories) and ULC S533 special locking arrangements component; listed to UL 10C and CAN/ULC S104 for fire doors rated up to 1-1/2 hours. 10 year limited warranty.

  • Field-selectable 15 or 30 second release delay, with 0 to 3 second nuisance delay
  • Up to 1,200 lbf (5,338 N) holding force; fail-safe
  • Auto-sensing 12 to 24 VDC; 490 mA at 12 VDC (base unit)
  • Built-in pressure sensor: no need to replace existing door hardware
  • Includes 960 keyswitch, building code sign and (base unit) 914 external sounder; DE8310-S has a built-in sounder
  • Local and remote monitoring through SPDT and DPDT dry-contact relays
  • Fire-rated: CAN/ULC S104 and UL 10C, 1-1/2 hours; 10 year limited warranty

Product Details

  • Built-in sensor detects when pressure is applied to outward swinging doors; no need to replace existing door hardware
  • Field-selectable 15 or 30 second release delay with field-selectable 0 to 3 second nuisance delay
  • Highly visible red/green light panel indicates the status of the door (local)
  • Includes 960 keyswitch for reset and override and a building code sign; the base unit (DE8310) includes a 914 external sounder
  • Dry-contact SPDT and DPDT relays provided for local and/or remote monitoring
  • Keyhole mounting for ease of installation
  • Convenient plug-in wiring harnesses
  • Easy-access wiring cavity
  • Stabilizing 4-bolt drop-stop mounting
  • Surge protection

Technical Details

DE8310

  • Dimensions: 10-13/16 in. W x 2-7/8 in. H x 2-1/8 in. D (275 mm x 73 mm x 54 mm), includes 1/4 in. (6 mm) mounting bracket

DE8310S

  • Dimensions: 11-3/4 in. W x 2-7/8 in. H x 2-1/8 in. D (299 mm x 73 mm x 54 mm), includes 1/4 in. (6 mm) mounting bracket
  • Armature plate: 7-7/16 in. W x 2-3/8 in. H x 5/8 in. D (190 mm x 61 mm x 16 mm)

Shared Technical Information

  • Holding force: up to 1,200 lbf (5,338 N)
  • Voltage: auto-sensing 12 to 24 VDC; 490 mA at 12 VDC (base unit)
  • Mode: fail-safe
  • Release delay: field-selectable 15 or 30 seconds; nuisance delay 0 to 3 seconds
  • Monitoring: local and remote relay outputs; optional built-in sounder
  • Provision for IBC, SBC, NFPA 101, UBC, BOCA or NBC of Canada compliance
  • Designed to overcome residual magnetism
  • Hardened steel armature nut
  • Includes self-drilling Teks® fasteners
  • Includes 5/8 in. (16 mm) armature plate
  • Finish: Brushed Anodized Aluminum (28)
  • Ability to synchronize up to 4 doors (with or without mullion) using a converter; please request further details (custom applications that require synchronization of 3 or 4 doors will require special AHJ approval)
  • UL 294 Special Locking Arrangements Component (6th edition)
  • ULC S533 Special Locking Arrangements Component (4th edition)
  • CAN/ULC S104 Auxiliary Locks, listed for fire doors rated up to 1-1/2 hours
  • UL 10C Auxiliary Locks, listed for fire doors rated up to 1-1/2 hours
  • Patents: US 8,292,337; Canada 2,632,243

Components

Optional

  • S: built-in sounder. The built-in sounder pulses slowly during the short nuisance delay, sounds steady through the release delay and continues until reset. If the door is forced open before the set release delay has lapsed, the sounder cannot be turned off without switching the system power off.

Accessories

  • BC1M-30: 30 second building code sign

Applications

  • Health care facilities
  • Retail and wholesale centers
  • Airports
  • Public transit buildings
  • Museums and galleries
DE8310 Delayed Egress Electromagenetic Lock