Product Details
- Built-in sensor detects when pressure is applied to outward swinging doors; no need to replace existing door hardware
- Field-selectable 15 or 30 second release delay with field-selectable 0 to 3 second nuisance delay
- Highly visible red/green light panel indicates the status of the door (local)
- Includes 960 keyswitch for reset and override and a building code sign; the base unit (DE8310) includes a 914 external sounder
- Dry-contact SPDT and DPDT relays provided for local and/or remote monitoring
- Keyhole mounting for ease of installation
- Convenient plug-in wiring harnesses
- Easy-access wiring cavity
- Stabilizing 4-bolt drop-stop mounting
- Surge protection
Technical Details
DE8310
- Dimensions: 10-13/16 in. W x 2-7/8 in. H x 2-1/8 in. D (275 mm x 73 mm x 54 mm), includes 1/4 in. (6 mm) mounting bracket
DE8310S
- Dimensions: 11-3/4 in. W x 2-7/8 in. H x 2-1/8 in. D (299 mm x 73 mm x 54 mm), includes 1/4 in. (6 mm) mounting bracket
- Armature plate: 7-7/16 in. W x 2-3/8 in. H x 5/8 in. D (190 mm x 61 mm x 16 mm)
Shared Technical Information
- Holding force: up to 1,200 lbf (5,338 N)
- Voltage: auto-sensing 12 to 24 VDC; 490 mA at 12 VDC (base unit)
- Mode: fail-safe
- Release delay: field-selectable 15 or 30 seconds; nuisance delay 0 to 3 seconds
- Monitoring: local and remote relay outputs; optional built-in sounder
- Provision for IBC, SBC, NFPA 101, UBC, BOCA or NBC of Canada compliance
- Designed to overcome residual magnetism
- Hardened steel armature nut
- Includes self-drilling Teks® fasteners
- Includes 5/8 in. (16 mm) armature plate
- Finish: Brushed Anodized Aluminum (28)
- Ability to synchronize up to 4 doors (with or without mullion) using a converter; please request further details (custom applications that require synchronization of 3 or 4 doors will require special AHJ approval)
- UL 294 Special Locking Arrangements Component (6th edition)
- ULC S533 Special Locking Arrangements Component (4th edition)
- CAN/ULC S104 Auxiliary Locks, listed for fire doors rated up to 1-1/2 hours
- UL 10C Auxiliary Locks, listed for fire doors rated up to 1-1/2 hours
- Patents: US 8,292,337; Canada 2,632,243
Components
Optional
- S: built-in sounder. The built-in sounder pulses slowly during the short nuisance delay, sounds steady through the release delay and continues until reset. If the door is forced open before the set release delay has lapsed, the sounder cannot be turned off without switching the system power off.
Accessories
- BC1M-30: 30 second building code sign
Applications
- Health care facilities
- Retail and wholesale centers
- Airports
- Public transit buildings
- Museums and galleries