Product Summary

As a furthter development of the AuditGard lock the Supra Series offers beside the base functions an increased number of users. Customised versions have to be created by adding functions via keypad or by using the LA GARD PC programming software.

Different input units - all in metal design - are available with a soft keypad or a foil keypad.

According to the safe application, a deadbolt or a swingbolt locking system can be chosen. The patented swingbolt technology offers a spindle-less system which moves the bolt by the operation of the bolt work.

Product Details

Approvals/Certificates

  • EN 1300 B, ECB-S, VdS class 2, DNV, UL type 1 

Power supply

  • 1 x 9 volt block battery (not included in delivery) or
  • 6 x 1.5 volt C-cell battery, recommended for time delay (not included in delivery)
  • External power supply by VdS certified alarm interface

Lock  

  • Die-cast lock case and bolt, bolt with 2 M4 threads (only for deadbolt)
  • Incl. 3 screws for lock mounting

Admissible mounting positions  

  • Deadbolt:
    • Right hand/left hand lock (upside down mounting), opening clockwise
  • Swingbolt:
    • Right hand/left hand lock (upside down mounting, dual-handed)

Technical Details

Input units

  • 3125
    • Order number: 82855
    • Input unit: Metal, satin chrome
    • Battery case: Separate battery box*
    • Key pad: Silicone
    • External power contact: Yes
    • Cable length: 457 mm (18”)
    • Spindle length: 152 mm (6”)
    • Deadbolt available: Yes
    • Swingbolt available: Yes
  • 3750-K
    • Order number: 82856
    • Input unit: Metal, satin chrome
    • Battery case: Integrated, 1 x 9 v block battery*
    • Key pad: Foil
    • External power contact: No
    • Cable length: 457 mm (18”)
    • Spindle length: 152 mm (6”)
    • Deadbolt available: Yes
    • Swingbolt available: Yes

* Not included in delivery

Options input units

  • Die-cast back plate (only for input unit 3125) - Option code: GZN

Lock

  • LA GARD 4300M
    • Order number: 82818
    • Swingbolt
  • LA GARD 6040M
    • Order number: 82815
    • Deadbolt, throw 8.7 mm

Options lock

  • Not grounded - Option code: POT

Accessories

  • Small battery box (1 x 9 volt block battery) - Order number: 82891/0001
  • Large battery box (6 x 1.5 volt C-cell battery) - Order number: 82891/0004
  • Small battery/alarm box (1 x 9 volt block battery), required for alarm functions - Order number: 82891/0002
  • Large battery/alarm box (6 x 1.5 volt C-cell battery), required for alarm functions - Order number: 82891/0006
  • Wall Plug Transformer 220 volt AC (EU-plug) with battery port connector, without VdS certificate - Order number: 82892/0011
  • Alarm Interface 871084-2, VdS listed - Order number: 82891/0007
  • Audit cable (for input unit 3125 only) - Order number: 82892/0002
  • Audit cable (for input unit 3750-K only) - Order number: 82892/0004
  • AuditGard Software-Kit (CD with Setup- and AuditView Software / USB-Adapter /
  • Cable for Entry Device 3125 / Cable for Entry Device 3750-K) - Order number: 82892/0022
  • Reset box (necessary to reset the operating mode to works mode) - Order number: 82894/0001
  • 9 volt alkaline block battery - Order number: 0 516 000 000
  • Screw for Swingbolt lock, 1/4 - 20 x 1.03 PH, with screw locking coating - Order number: 1 269 902 610
  • Screw for Deadbolt lock, 1/4 - 20 x 1-7/32 PH, with screw locking coating - Order number: 1 269 903 090

Functionalities

Codes

  • 1 Master
  • 1 Manager
  • 30 Users

Lock functions

  • Time Delay 00-99 minutes and opening delay 00-19 minutes configurable
  • opening delay bypassing (user ID #31)*
  • Dual Mode*
  • Time Delay Override*
  • Add/Delete User code (Manager only)
  • Enable/Disable User code (Manager only)
  • Add/Delete Manager code (Master only)
  • Enable/Disable Manager code (Master only)
  • Remote disable lock opening (shuts the opening of the lock in spite of a correct code) **/***
  • Silent Alarm***
  • Audit (record of the last 512 events)
  • Master reset (Master and Manager in combination are able to set the lock in the pre-setup mode (factory setting), the whole configuration will be reset here)

* Must be configurated by the initial configuration, subsequently it can just be enable/disable by master reset and reconfiguration

** Activation by PC software required
*** Battery box with alarm function or separate Alarm Interface (VdS listed) required

General functions

  • Low battery signal
  • Wrong try lockout after 4 false codes

Safe Lock La Gard - Input unit 3190
Safe Lock La Gard - Input unit 3047
Safe Lock La Gard - Input unit 3750

Can’t find what you’re looking for?